Socket Weld Flange
Size Range: 1/2”to 4” Pressure Class: 150# / 300# / 600# / 900# / 1500# / 2500#
View productWhen a project needs a defined route for power, control or communication cables, this hdpe electrical conduit pipe is extruded as one continuous polyethylene wall with no welded seam, no inner liner and no applied coating, so the bore stays clear once the trench is compacted. For long runs beneath roads, yards and building slabs, specifying an underground hdpe electrical conduit allows the duct to be carried into the trench and lined up by two people, or installed by directional drilling at crossings.
The duct is extruded as one continuous polyethylene wall and supplied in lengths that two people can carry into a trench and line up by hand. There is no welded seam, no inner liner and no applied coating to fail after backfill — the pipe leaves production with a smooth matte surface and a light printed marking running along its length.
Polyethylene does not corrode, so a duct under the water table, in coastal fill or beneath irrigated land behaves exactly like one in dry soil. There is no coating to scratch during backfill and no rust staining at the surface.
The inner wall is smooth and continuous, so draw ropes, swabs and rollers travel without snagging. The circular profile stays clear once the trench is compacted, provided the bed is prepared properly.
The wall is stiff enough to hold a circular section under backfill, yet ductile enough to flex and recover rather than crack. Longer supply lengths reduce the number of joints on a straight run.
The points below describe how this duct is built and finished. Duct size, length schedule and joint details are confirmed against the project drawing before an order is accepted.
| Material | High-density polyethylene (HDPE). |
|---|---|
| Form | Rigid, round duct, extruded as one continuous wall. |
| Construction | Single wall — no welded seam, no inner liner and no applied coating. |
| Surface and finish | Smooth matte surface with a light printed marking running along the length. |
| Behaviour underground | Polyethylene does not corrode, so there is no coating to damage during backfill and no rust staining. |
| Bore | Smooth, continuous inner wall so draw ropes, swabs and rollers travel without snagging. |
| Jointing | Solvent-cemented joints are not used; the jointing method is confirmed per order. |
| Fittings | Matching pipe fittings for changes of direction, terminations and chamber or cabinet entries. |
| Installation methods | Placement by hand in an open trench, and directional drilling for crossings. |
| Supplied lengths | Long supply lengths that reduce the number of joints on a straight run; the length schedule is set per order. |
Two things shape the quotation: where the duct runs, and how the joints are made. Send those details with the drawing and the quotation reflects the actual job.
The intended service is buried power, control and communication cable routes. The duct suits trenches, duct banks, crossings, under roads, yards and building slabs.
Where an open excavation is impractical, the duct can be installed by directional drilling. Send the crossing length and the pull details so the crossing can be reviewed against the route drawing before supply.
Lengths can be carried into a trench and lined up by two people, and long supply lengths cut the number of joints on a straight run. The rigid circular profile holds the bore once the trench is compacted, provided the bed is prepared properly.
Under hardstanding, yards and building slabs the duct forms a clear passage for later cable pulls, and matching fittings take the run into chambers or cabinets at terminations.
Because polyethylene does not corrode, a duct under the water table, in coastal fill or beneath irrigated land behaves exactly like one in dry soil, with no rust staining to track the route later.
Working through these points before the order is placed keeps the quotation aligned with the installed job.
Send the drawing and length schedule along with the cable and route details, and the quotation will be prepared against the installed job.
it is made from high-density polyethylene (hdpe) and extruded as one continuous wall. the construction is single wall — there is no welded seam, no inner liner and no applied coating. the surface is a smooth matte finish with a light printed marking running along the length.
no coating is applied. polyethylene does not corrode, so a duct under the water table, in coastal fill or beneath irrigated land behaves exactly like one in dry soil — there is no coating to scratch during backfill and no rust staining.
solvent-cemented joints, as used with electrical pvc pipe, are not part of this product. the jointing method is confirmed per order, and matching pipe fittings are available for changes of direction, terminations and chamber or cabinet entries.
yes. for crossings the duct can be installed by directional drilling. send the crossing length and the pull details so the run can be reviewed against your drawing.
send the drawing together with the duct size, cable details, depth, bends and access points, jointing method and length schedule. for crossings, add the crossing length and pull details.
if the project needs a particular marking, a colour match or a cut length, note it when you send the schedule and what can be done will be confirmed before the order is placed.